Utility Commands
470
ProSAFE M7100 Managed Switches
no sflow sampler
Use this command to reset the sFlow sampler instance to the default settings.
sflow poller
A data source configured to collect counter samples is called a poller. Use this command to enable
a new sFlow poller instance for this data source if the <rcvr_idx> parameter is valid.
no sflow poller
Use this command to reset the sFlow poller instance to the default settings.
Field Description
Receiver Index The sFlow Receiver for this sFlow sampler to which flow samples are to be sent. A value of
zer
o (0) means that no receiver is configured, no packets will be sampled. Only active
receivers can be set. If a receiver expires, then all samplers associated with the receiver will
also expire. Possible values are 1-8. The default is 0.
Maxheadersize The maximum number of bytes that should be copied from the sampler packet. The range is
20-256. The def
ault is 128. When se
t to zero (0), all the sampler parameters are set to their
corresponding default value.
Sampling Rate The statistical sampling rate for packet sampling from this source. A sampling rate of 1
c
ounts all pack
ets. A value of zero (0) disables sampling. A value of N means that out of N
incoming packets, 1 packet will be sampled. The range is 1024-65536 and 0. The default is
0.
Format no sflow sampler {<rcvr-indx> | rate <sampling-rate> | maxheadersize
<size>}
Mode Interface Config
Format sflow poller {<rcvr-indx> | interval <poll-interval>}
Mode Interface Config
Field Description
Receiver Index Enter the sFlow Receiver associated with the sampler/poller. A value of zero (0) means that
no rec
eiver is configured. The range is 1-8. The default is 0.
Poll Interval Enter the sFlow instance polling interval. A poll interval of zero (0) disables counter sampling.
When set t
o zero (0), all the poller parameters are set to their corresponding default value.
The range is 0-86400. The default is 0. A value of N means once in N seconds a counter
sample is generated.
Format no sflow poller {<rcvr-indx> | interval <poll-interval>}
Mode Interface Config

Table of Contents

Other manuals for NETGEAR ProSAFE M7100-24X

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NETGEAR ProSAFE M7100-24X and is the answer not in the manual?

NETGEAR ProSAFE M7100-24X Specifications

General IconGeneral
BrandNETGEAR
ModelProSAFE M7100-24X
CategorySwitch
LanguageEnglish

Related product manuals