Utility Commands
479
ProSAFE M7100 Managed Switches
no rmon alarm
This command deletes the rmon alarm entry.
rmon hcalarm
This command sets the rmon hcalarm entry in the high capacity RMON alarm MIB group.
Format no rmon alarm <alarm number>
Mode Global Config
Format rmon hcalarm <alarm number> <variable> <sample interval> <sampling
type> rising-threshold high <value> low <value> status {positive |
negative} [<rising-event-index>] falling-threshold high <value> low
<value> status {positive | negative} [<falling-event-index>]
[startup {rising | falling | rising-falling}] [owner <string>]
Mode Global Config
Parameter Description
hcalarm alarm
number
The identifier of the high capacity alarm instance.
High Capacity Alarm
V
ariable
The objec
t identifier of the particular variable to be sampled. Only variables that resolve
to an ASN.1 primitive type of integer.
High Capacity Alarm
inter
val
The interval in seconds over which the data is sampled and compared with the rising and
falling thresholds. The range is 1to 2147483647.
High Capacity Alarm
Sample Type
The me
thod of sampling the selected variable and calculating the value to be compared
against thresholds. Possible types are Absolute or Delta.
Rising-Threshold
High Value
High c
apacity alarm rising threshold absolute value high. The upper 32 bits of the
absolute value for threshold for the sampled statistics.
Rising-Threshold
Low V
alue
High capacity alarm rising threshold absolute value low. The lower 32 bits of the absolute
value for threshold for the sampled statistics.
High Capacity Alarm
Rising-Thr
eshold
Value Status
The validity and sign of the data for the rising threshold. Possible values are positive and
negative.
High Capacity Alarm
Rising E
v
ent Index
The index of the event entry that is used when a rising threshold is crossed. The range is
1 to 65535. The default is 1.
Falling-Threshold
High Value
High c
apacity alarm falling threshold absolute value high. The upper 32 bits of the
absolute value for threshold for the sampled statistic.
Falling-Threshold
Low V
alue
High capacity alarm falling threshold absolute value high. The upper 32 bits of the
absolute value for threshold for the sampled statistic.
High Capacity Alarm
Falling-
Threshold
Value Status
The validity and sign of the data for the falling threshold. Possible values are positive and
negative.