Utility Commands
368
ProSAFE M7100 Managed Switches
filedescr
This command associates a given text description with an image. Any existing description will be
replaced. For stacking, the optional <unit> parameter identifies the node on which this
command must be executed. When this parameter is not supplied, the command is executed on
all nodes in a Stack.
update bootcode
This command updates the bootcode (boot loader) on the switch. The bootcode is read from the
active-image for subsequent reboots. The optional <unit> parameter is valid only on stacks. If
you enter this parameter for a standalone system, and error message is displayed. For stacking,
the <unit> parameter identifies the node on which this command must be executed. When this
parameter is not supplied, the command is executed on all nodes in a stack.
System Information and Statistics Commands
This section describes the commands you use to view information about system features,
components, and configurations.
process cpu threshold
Use this command to configure the CPU utilization thresholds. The Rising and Falling thresholds
are specified as a percentage of CPU resources. The utilization monitoring time period can be
configured from 5 seconds to 86,400 seconds in multiples of 5 seconds. The CPU utilization
threshold configuration is saved across a switch reboot. Configuring the falling utilization
threshold is optional. If the falling CPU utilization parameters are not configured, they take the
same value as the rising CPU utilization parameters.
Format filedescr [<unit>] {image1 | image2} <text-description>
Mode Privileged EXEC
Format update bootcode [<unit>]
Mode Privileged EXEC
Format process cpu threshold type total rising <1-100> interval <5-86400>
[falling <1-100> interval <5-86400>]
Mode Global Config
Parameter Description
rising threshold The percentage of CPU resources that, when exceeded for the configured rising interval,
triggers a notific
ation. The range is 1–100. The default is 0 (disabled).
rising interval The duration of the CPU rising threshold violation, in seconds, that must be met to trigger
a notific
ation. The range is 5–86,400. The default is 0 (disabled).