Error Troubleshooting
Phaser 7100 Service Manual Xerox Internal Use Only2-362
116-714 HP-GL/2 Command ERR
HP-GL/2 command error occurred.
Applicable Fault Code
• 116-714: A HP-GL command error was detected.
Initial Actions
• Power cycle the printer.
• If the problem persists, perform the following procedure
.
116-715 Max Form to PLW Registered
The PLW form data cannot be registered because of the restriction on the number of forms.
Applicable Fault Code
• 116-715: <PLW form registration error> The PLW form data cannot be registered because of the
restriction on the number of forms.
Initial Actions
• Power cycle the printer.
• If the problem persists, perform the following procedure
.
Troubleshooting Procedure
Step Actions and Questions
1. Correct or remove the data in the print data that causes the error.
If the problem persists (when HDD failure is suspected), go to:
• Network Troubleshooting on page 2-459
• Printing can be performed but Abnormally on page 2-410
Troubleshooting Procedure
Step Actions and Questions
1. After checking the registered forms using the Operation Panel utility, delete the unnecessary
forms/logos.
Or, delete the unnecessary forms with Print Command.