Error Troubleshooting
Phaser 7100 Service Manual Xerox Internal Use Only2-432
Motor Troubleshooting
Belt Retract Motor
Troubleshooting Reference
Applicable Parts Wiring and Plug/Jack Map References
•Front Harness Assembly, PL 4.2.11
Belt Retract Sensor (IBT Retract Cam Assembly), PL 9.1.8
MCU PWB, PL 12.1.15
Main Harness Assembly, PL 12.3.1
Transfer on page 7-54
Troubleshooting Procedure
Step Actions and Questions Yes No
1. Check the Belt Retract Motor operation.
Perform DC330 Component Control on
page 2-26 [094-001] to check the operation of
the Belt Retract Motor.
Is the Belt Retract Motor operating properly?
Replace the MCU PWB
(REP 12.4 MCU PWB
on page 4-206).
Go to step 2.
2. Check the connection between the Belt Retract
Motor and MCU PWB.
Are the connectors P/J4662, P/J4661, and P/J466
connected securely?
Go to step 3. Connect the
connectors P/J4662,
P/J4661, and P/J466.
3. Check the conductivity between the Belt Retract
Motor and Relay Connector.
Is the connection between P/J4662 <=> P/J4661
conducting properly?
Go to step 4. Replace the Front
Harness Assembly.
4. Check the conductivity between the Relay
Connector and MCU PWB.
Is the connection between P/J4661 <=> P/J466
conducting properly?
Go to step 5. Replace the Main
Harness Assembly.
5. Check the voltage supply (+24VDC) to the Belt
Retract Motor.
Measure the voltage between the MCU PWB
GND <=> P/J466-3.
Is there a voltage (approx. +24VDC) output?
Replace the IBT
Retract Cam Assembly
(REP 9.6 IBT Retract
Cam Assembly on
page 4-168).
Go to +24VDC Power
Troubleshooting on
page 2-455.

Table of Contents