Error Troubleshooting
Xerox Internal Use Only Phaser 7100 Service Manual 2-305
(Y/ M/ C/ K) Deve Motor Fail
The Developer Motor (Y/ M/ C/ K) rotation error was detected.
Applicable Fault Codes
093-318: Deve Y Motor Fail
093-319: Deve M Motor Fail
093-320: Deve K Motor Fail
093-325: Deve C Motor Fail
Initial Actions
Power cycle the printer.
If the problem persists, perform the following procedure.
Troubleshooting Reference
Applicable Parts Wiring and Plug/Jack Map References
Developer Motor PWB, PL 11.1.16
Developer Motor Assembly, PL 11.1.17
Developer Motor Harness Assembly, PL 11.1.24
MCU PWB, PL 12.1.15
LVPS PWB, PL 12.2.1
Main Harness Assembly, PL 12.3.1
Drive 2/ Bypass Tray on page 7-45
Troubleshooting Procedure
Step Actions and Questions Yes No
1. Check the Developer Motor (Y/ M/ C/ K)
operation.
Perform DC330 Component Control on
page 2-26 to check the rotation of the Deve
Motor (Y/ M/ C/ K).
(Y) Developer Motor [091-007]
(M) Developer Motor [091-009]
(C) Developer Motor [091-011]
(K) Developer Motor [091-003]
Is the Motor working properly?
Replace the MCU PWB
(REP 12.4 MCU PWB
on page 4-206).
Go to step 2.
2. Check the connection between the Developer
Motor (Y/ M/ C/ K) and Developer Motor PWB.
Is the Flat Cable connected securely?
Go to step 3. Connect the Flat
Cable.