Xerox Internal Use Only Phaser 7100 Service Manual 2-437
Duplex Motor
Troubleshooting Reference
Applicable Parts Wiring and Plug/Jack Map References
Duplex Harness Assembly, PL 4.2.18
MCU PWB, PL 12.1.15
Main Harness Assembly, PL 12.3.1
Duplex Motor, PL 14.2.1
Duplex PWB, PL 14.3.8
Option Duplex Sensor Harness Assembly, PL 14.3.9
Duplex on page 7-62
Troubleshooting Procedure
Step Actions and Questions Yes No
1. Check the Duplex Motor operation.
Perform DC330 Component Control on
page 2-26 [071-024] to check the operation of
the Duplex Motor.
Is the Duplex Motor operating properly?
Replace the MCU PWB
(REP 12.4 MCU PWB
on page 4-206).
Go to step 2.
2. Check the connection between the Duplex Motor
and Duplex PWB.
Is the connector P/J429 connected securely?
Go to step 3. Connect the connector
P/J429.
3. Check the voltage supply (+24VDC) to the
Duplex Motor.
Measure the voltages between the Duplex PWB
GND <=> P/J429-1 and Duplex PWB GND <=>
P/J429-2.
Is there a voltage (approx. +24VDC) output?
Close the Interlock Switch and check.
Replace the Duplex
Motor (REP 14.2
Duplex Motor on
page 4-250).
Go to step 4.
4. Check the voltage supply (+24VDC) to the
Duplex PWB.
Measure the voltages between the Duplex PWB
GND <=> P/J428-4 and Duplex PWB GND <=>
P/J428-5.
Is there a voltage (approx. +24VDC) output?
Close the Interlock Switch and check.
Replace the Duplex
PWB (REP 14.6 Duplex
PWB on page 4-257).
Go to step 5.
5. Check the voltage output (+24VDC) from the
MCU PWB.
Measure the voltages between the MCU PWB
GND <=> P/J467-4 and MCU PWB GND <=>
P/J467-5.
Is there a voltage (approx. +24VDC) output?
Go to step 6. +24VDC Power
Troubleshooting on
page 2-455