Error Troubleshooting
Phaser 7100 Service Manual Xerox Internal Use Only2-438
6. Check the connection between the Duplex PWB
and MCU PWB.
Are the connectors P/J428, P/J4672, P/J4671,
and P/J467 connected securely?
Replace the
following parts in
sequence:
• Duplex Relay
Harness Assembly
•Duplex Harness
Assembly
•Main Harness
Assembly
Connect the
connectors P/J428,
P/J4672, P/J4671,and
P/J467.
Troubleshooting Procedure (Continued)
Step Actions and Questions Yes No