Error Troubleshooting
Xerox Internal Use Only Phaser 7100 Service Manual 2-83
Fuser Unit Fail
The Fuser Unit has failed due to one of the following problems.
A differential circuit output error was detected between the detection output and the
compensation output of the Fuser Unit NC Sensor.
When the Lamp On time meets the following conditions, where Tws °C is the temperature at the
Wait state start time that is obtained at the NCSCenter.
The temperature monitor AD value of the STS-Front was detected to be higher than T[HITMP (2)]
3 times in a row.
During Warm Up Control, an abnormal detected temperature due to NC Sensor malfunction or
poor contact was detected.
The Fuser Unit Main Lamp or Sub Lamp has been On continuously for longer than the setting time
(NVM).
At the first Lamp Off after it was turned On, the NC temperature is continuously at
EP_U4_LOW_NC °C or lower 8 or more times in a row.
The Thermistor disconnection detected.
At the first Heater OFF after it was turned On, the detected temperature at the edge STS is
continuously at EP_U4_LOW_STS °C or lower 8 or more times in a row.
Notified at the moment the Relay is cut off from the circuit.
The detected temperature at the NC or the STS has not changed during this period, although the
Main Lamp has been On continuously for 15 s or longer.
The Cool Down Mode has continued for EP_U4_COOL_TIME * 10 s or longer.
Applicable Fault Codes
010-311: Fuser Unit Heat Roll STS-1 Disconnection Fail
010-319: Fuser Unit NC Sensor Differential Amp Fail
010-328: Fuser Unit Warm Up Time Fail (Not Ready)
010-331: Heat Roll STS Over Temperature Fail
010-332: Heat Roll NC Sensor Disconnection Fail
010-333: Heat Roll NC Sensor Over Temperature Fail
010-334: Heat Roll NC Sensor Broken Fail
010-335: Heat Roll NC Sensor Range Fail
010-338: Fuser Unit On Time Fail
010-339: Heat Roll NC Sensor Low Temperature Fail
010-340: Fuser Unit Detached
010-344: Heat Roll STS Sensor Low Temperature Fail
010-345: Fuser Unit Hard Relay Off Fail
010-346: Fuser Main Lamp Data Renewal Fail
010-347: Fuser Sub Lamp Data Renewal Fail
010-355: Fuser Cool Down Timeout Fail