Service Parts Disassembly
Xerox Internal Use Only Phaser 7100 Service Manual 4-91
REP 4.5 Front Frame Sub Assembly
PL 4.2.9
WARNING: The Fuser may be hot. Turn the printer power Off and allow at least 30 minutes for
the Fuser to cool before removing the Fuser.
1. Remove Tray 1.
2. Remove the Fuser Unit (REP 10.1 Fuser Unit on page 4-183).
3. Remove the Transfer Roller (2nd BTR Unit) (REP 4.10 Transfer Roller (2nd BTR Unit) on
page 4-108).
4. Remove the I/P PWB Cover Assembly (REP 1.5 Image Processor (I/P) PWB Cover Assembly on
page 4-19).
5. Remove the Rear Cover (REP 1.6 Rear Cover on page 4-20).
6. Remove the Left Side Cover (REP 1.10 Left Side Cover on page 4-25).
7. Remove the Right Side Cover (REP 1.11 Right Side Cover on page 4-27).
8. Remove the Left Feeder Cover (REP 2.10 Left Feeder Cover on page 4-49).
9. Remove the Right Feeder Cover (REP 2.3 Right Feeder Cover on page 4-40).
10. Remove the Control Panel Assembly (REP 1.12 Control Panel Assembly on page 4-29).
11. Remove the Bypass Tray Assembly (REP 3.5 Bypass Tray Assembly on page 4-73).
12. Remove the Bypass Tray Cover (REP 3.3 Bypass Tray Cover Assembly/ Exit 1 Cover/ Exit 2 Cover on
page 4-71).
13. Remove the Front Cover Assembly (REP 1.15 Front Cover Assembly on page 4-35).
14. Remove the Front Frame Assembly (REP 4.1 Front Frame Assembly on page 4-74).
15. Remove the Right Latch Lever/ Left Latch Lever/ Latch Spring (REP 4.4 Right/ Left Latch Lever,
Latch Spring on page 4-89).
16. Remove the Lever Shaft Assembly (PL 4.2.2).
17. Remove the Fuser Drive Assembly (REP 4.7 Fuser Drive Assembly on page 4-99).
18. Remove the Chute Assembly (REP 4.8 Chute Assembly on page 4-103).