EasyManua.ls Logo

Xerox Phaser 7100

Xerox Phaser 7100
1146 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error Troubleshooting
Xerox Internal Use Only Phaser 7100 Service Manual 2-415
X,X,X,X O,O,X,X DDR memory read check & zero
clear has completed
RAM ON: RAM Error
X,X,X,X O,O,X,O Copy to memory for Panbug
program (TEXT portion)
ROM/
RAM
ON: ROM/ RAM
Error
X,X,X,X O,O,O,X Copy to memory for Panbug
program (BASE portion)
ROM/
RAM
ON: ROM/ RAM
Error
X,X,X,X O,O,O,O FPU register test has completed I/P PWB ON: I/P PWB Error
X,X,X,O X,X,X,X Jump preparation to CCode has
completed
I/P PWB ON: I/P PWB Error
X,X,O,X X,O,X,X Standard RAM diagnostic start RAM ON: Standard
RAM Error
116-315
X,X,O,X X,O,X,O Standard RAM diagnostic
completed
X,X,O,X X,O,O,X Extension RAM diagnostic start RAM ON: Extension
RAM Error
116-316
X,X,O,X X,O,O,O Extension RAM diagnostic
completed
X,X,O,X O,X,X,X Standard ROM diagnostic start ROM ON: Standard
ROM Error
116-317
X,X,O,X O,X,X,O Standard ROM diagnostic
completed
X,X,O,X O,X,O,X NVRAM diagnostic start NVM/
I/P PWB
ON: NVRAM Error 116-323
X,X,O,X O,X,O,O NVRAM diagnostic completed
X,X,O,O X,X,X,O Transition from MiniOS to
CORE (DIAG) completed
O,O,X,X X,X,O,X UI Cable Disconnect Detection UI/ I/P
PWB
ON: UI Cable
Connection Error
116-326
O,O,X,X X,X,O,O MCU Harness Disconnect
Detection
MCU/
I/P PWB
ON: MCU
Harness
Connection Error
116-328
X,O,X,X X,X,X,X IO ASIC diagnostic start I/P PWB ON: ASIC Error
X,O,X,X X,X,X,O IO ASIC diagnostic completed
Assessment Based on LED ON/ OFF States (Continued)
Main Unit
Lower
Main Unit
Upper
State/ Condition
Related
H/W
Failure
Location/
Details
Chain-Link
7,6,5,4 3,2,1,0

Table of Contents