Switching Commands
143
ProSAFE M7100 Managed Switches
The following shows example CLI display output for the command.
(Switch) #show lldp remote-device detail 0/7
LLDP Remote Device Detail
Local Interface: 0/7
Remote Identifier: 2
Chassis ID Subtype: MAC Address
Chassis ID: 00:FC:E3:90:01:0F
Port ID Subtype: MAC Address
Port ID: 00:FC:E3:90:01:11
System Name:
System Description:
Port Description:
System Capabilities Supported:
System Capabilities Enabled:
Time to Live: 24 seconds
Chassis ID
Subtype
The type of identification used in the Chassis ID field.
Chassis ID The chassis of the remote device.
Port ID Subtype The type of port on the remote device.
Port ID The port number that transmitted the LLDPDU.
System Name The system name of the remote device.
System
Description
Describes the remote system by identifying the system name and versions of hardware,
oper
ating s
ystem, and networking software supported in the device.
Port Description Describes the port in an alpha-numeric format. The port description is configurable.
System
C
apabilities
Suppor
ted
Indicates the primary function(s) of the device.
System
Capabilities
Enabled
Shows which of the suppor
ted system capabilities are enabled.
Management
Addres
s
For each interface on the remote device with an LLDP agent, lists the type of address the
remote LLDP agent uses and specifies the address used to obtain information related to the
device.
Time To Live
The amount of time (in seconds) the remote device's information received in the LLDPDU
should be treated as valid information.
Term Definition