SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
123
2 Parameters
2.2 List of parameters
Example:
p1500 = 6 --> the macro file PM000006.ACX is run.
Dependency: Refer to: p0015, p0700, p1000, r8573
Notice: No errors were issued during quick commissioning (p3900 = 1) when writing to parameters of the QUICK_IBN group!
When executing a specific macro, the corresponding programmed settings are made and become active.
Note: The macros in the specified directory are displayed in r8573. r8573 is not in the expert list of the commissioning
software.
Macros available as standard are described in the technical documentation of the particular product.
CI: Connector Input
Description: Setting to change the direction of rotation.
Changing the parameter reverses the direction of the encoder actual value.
Value: 0: CW
1: CCW
Notice: An appropriate fault is output for a drive data set changeover where the direction of rotation changes and the pulses
are enabled.
Description: Sets the reference quantity for speed.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
Dependency: Refer to: p2001, p2002, p2003, r2004
Description: Sets the reference quantity for voltages.
The reference quantity corresponds to 100% or 4000 hex (word) or 4000 0000 hex (double word).
Note: For the automatic calculation (p0340 = 1, p3900 > 0) an appropriate pre-assignment is only made if the parameter is
not inhibited from being overwritten using p0573 = 1.
If a BICO interconnection is established between different physical quantities, then the particular reference quantities
are used as internal conversion factor.
For infeed units, the parameterized device supply voltage (p0210) is pre-assigned as the reference quantity.
Example:
The actual value of the DC link voltage (r0070) is connected to a test socket (e.g. p0771[0]). The actual voltage value
is cyclically converted into a percentage of the reference voltage (p2001) and output according to the parameterized
scaling.
p1821[0...n] Dir of rot / Dir of rot
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(1, 4) Calculated: - Access level: 3
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 4704, 4710,
4711
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p2000 Reference speed / n_ref
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: T Calculated: CALC_MOD_ALL Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3113, 9566,
9568, 9572
P-Group: Communications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
6.00 [rpm] 210000.00 [rpm] 210000.00 [rpm]
p2001 Reference voltage / Reference voltage
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: T Calculated: CALC_MOD_ALL Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Communications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
10 [Vrms] 100000 [Vrms] 1000 [Vrms]