2 Parameters
2.2 List of parameters
SINAMICS DCM
332 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Selects the address of the SINAMICS Link sender from which the process data (PZD) is received.
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
[9] = PZD 10
[10] = PZD 11
[11] = PZD 12
[12] = PZD 13
[13] = PZD 14
[14] = PZD 15
[15] = PZD 16
Dependency: Refer to: p8870
Note: Value range:
0: Not used
1 ... 64: Address
A change only becomes effective after POWER ON, reset, project download or p8842 = 1.
Description: Displays the bus address of sender from which the PZD is received.
Index: [0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
[8] = PZD 9
p8872[0...15] SINAMICS Link address receive PZD / Link addr recv
CU_DC (PROFINET
CBE20), CU_DC_R
(PROFINET CBE20),
CU_DC_R_S
(PROFINET CBE20),
CU_DC_S
(PROFINET CBE20),
DC_CTRL (PROFINET
CBE20), DC_CTRL_R
(PROFINET CBE20),
DC_CTRL_R_S
(PROFINET CBE20),
DC_CTRL_S
(PROFINET CBE20),
TM150 (PROFINET
CBE20), TM15DI_DO
(PROFINET CBE20),
TM31 (PROFINET
CBE20)
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Communications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 64 0
r8874[0...63] IF2 diagnostics bus address PZD receive / IF2 diag addr recv
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Communications Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -