EasyManua.ls Logo

Siemens SINAMICS DCM - RFG Final Rounding 1; RFG Fin Rndg 1; RFG Initial Rounding 1; RFG Init Rndg 1; RFG Ramp-Down Time 1; RFG T_Ramp-Dn 1

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
438 List Manual (LH8), 02/2015, 6RX1800-0ED76
Note: The parameter is effective in the following cases:
- No quick stop (OFF3) active
- No other ramp-function generator parameter set selected
- No selection via ramp-up integrator
Description: Sets the ramp-down time for ramp-function generator parameter set 1.
Note: The parameter is effective in the following cases:
- No quick stop (OFF3) active
- No other ramp-function generator parameter set selected
- No selection via ramp-up integrator
Description: Sets the initial rounding for ramp-function generator parameter set 1.
Dependency: Refer to: p50295
Note: The parameter is effective in the following cases:
- No quick stop (OFF3) active
- No other ramp-function generator parameter set selected
- No selection via ramp-up integrator
Description: Sets the final rounding for ramp-function generator parameter set 1.
Dependency: Refer to: p50295
Note: The parameter is effective in the following cases:
- No quick stop (OFF3) active
- No other ramp-function generator parameter set selected
- No selection via ramp-up integrator
p50304[0...n] RFG ramp-down time 1 / RFG t_ramp-dn 1
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 650.00 [s] 10.00 [s]
p50305[0...n] RFG initial rounding 1 / RFG init rndg 1
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 100.00 [s] 0.00 [s]
p50306[0...n] RFG final rounding 1 / RFG fin rndg 1
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 100.00 [s] 0.00 [s]