2 Parameters
2.2 List of parameters
SINAMICS DCM
564 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output for the conversion result at analog input 6 (X177.7/8) on the CUD.
Description: Display and connector output for analog output 0 (X177.49/50) on the CUD.
Dependency: Refer to: p50750
Note: AO: Analog Output
Description: Display and connector output for analog output 1 (X177.51/52) on the CUD.
Dependency: Refer to: p50755
Note: AO: Analog Output
Description: Display and connector output for the braking distance required as increments of the pulse encoder defined in p0400.
The pulse encoder to be used must be selected using p50331.
The required braking distance is calculated assuming that the speed setpoint at the ramp-function generator input
has been set to 0 and the speed actual value is approaching 0, taking the set ramp-down time and roundings into
consideration.
Note: For p0400[p50331] = 0, a braking distance of 0 is displayed.
The braking distance calculation is only correct if the ramp-down time and the roundings do not change during
braking (p50302, r00899.5, p50637, p50638).
r52025 CO: CUD analog input 6 result / CUD AI 6 res
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52026 CO: CUD analog output 0 value after smoothing / CUD AO 0 v aft sm
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2095
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52027 CO: CUD analog output 1 value after smoothing / CUD AO 1 v aft sm
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2095
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52047 CO: Ramp-function generator braking distance (Unsigned32) / RFG brake dist U32
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: 3152
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -