2 Parameters
2.2 List of parameters
SINAMICS DCM
496 List Manual (LH8), 02/2015, 6RX1800-0ED76
[5] = Effective negative current limit
[6] = Effective speed controller proportional gain
Description: Sets the signal source to enable the negative direction of rotation.
Dependency: Refer to: p50672
Note: 1 signal: Negative direction of rotation enabled
0 signal: Negative direction of rotation disabled
Description: Sets the signal source to enable the positive direction of rotation.
Dependency: Refer to: p50671
Note: 1 signal: Positive direction of rotation enabled
0 signal: Positive direction of rotation disabled
Description: Sets the signal source to increase the setpoint for the motorized potentiometer.
Dependency: Refer to: p50471
Note: This parameter is only effective in manual mode (p50471 = 0).
Description: Sets the signal source to lower the setpoint for the motorized potentiometer.
Dependency: Refer to: p50471
Note: This parameter is only effective in manual mode (p50471 = 0).
p50671[0...n] BI: Setpoint processing sig source to enable neg dir of rotation / Ena n dir r sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1
p50672[0...n] BI: Setpoint processing signal source to enable pos dir of rotation / Ena p dir r sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1
p50673[0...n] BI: Motorized potentiometer signal source to increase setpoint / MotP incr sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50674[0...n] BI: Motorized potentiometer signal source to lower setpoint / MotP lower sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: CDS, p0170 Func. diagram: 3110
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0