SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
625
2 Parameters
2.2 List of parameters
Description: Display and connector output for raw values when measuring current actual values.
The following applies:
- 0 corresponds to approx. 3 x device rated current in negative direction
- 32767 corresponds to 0 A
- 65535 corresponds to approx. 3 x device rated current in positive direction
Index: [0] = Armature current 1
[1] = Armature current 2
Dependency: Refer to: r52921, r52922
Note: This parameter is used solely for internal diagnostics.
Description: Display and connector output for the scan values of line voltages UV, WV, WU.
Index: [0] = Line voltage UV
[1] = Line voltage VW
[2] = Line voltage WU
[3] = Field line voltage
Description: Display and connector output for the armature voltage/field voltage scan values.
Index: [0] = Scan values of Ua
[1] = Scan values of Uf
Description: Display and connector output for the armature current and field current scan values.
r52923[0...1] CO: Measurement results current actual values raw values / Meas res I_act raw
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: 8054
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r52950[0...3] CO: Line voltages scan values / V_line sc values
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950, 6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r52951[0...1] CO: Armature voltage/field voltage scan values / Ua/Uf scan_values
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6902, 6950,
6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r52952[0...3] CO: Armature current/field current scan values / Ia/If sc_values
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6850, 6851,
6912
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]