EasyManua.ls Logo

Siemens SINAMICS DCM - CO: Armature Current;Field Current Scan Values; CO: Armature Voltage;Field Voltage Scan Values; CO: Line Voltages Scan Values; V_Line Sc Values; CO: Measurement Results Current Actual Values Raw Values

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
625
2 Parameters
2.2 List of parameters
Description: Display and connector output for raw values when measuring current actual values.
The following applies:
- 0 corresponds to approx. 3 x device rated current in negative direction
- 32767 corresponds to 0 A
- 65535 corresponds to approx. 3 x device rated current in positive direction
Index: [0] = Armature current 1
[1] = Armature current 2
Dependency: Refer to: r52921, r52922
Note: This parameter is used solely for internal diagnostics.
Description: Display and connector output for the scan values of line voltages UV, WV, WU.
Index: [0] = Line voltage UV
[1] = Line voltage VW
[2] = Line voltage WU
[3] = Field line voltage
Description: Display and connector output for the armature voltage/field voltage scan values.
Index: [0] = Scan values of Ua
[1] = Scan values of Uf
Description: Display and connector output for the armature current and field current scan values.
r52923[0...1] CO: Measurement results current actual values raw values / Meas res I_act raw
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: 8054
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r52950[0...3] CO: Line voltages scan values / V_line sc values
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6950, 6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r52951[0...1] CO: Armature voltage/field voltage scan values / Ua/Uf scan_values
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6902, 6950,
6952
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: p2001 Expert list: 1
Min Max Factory setting
- [V] - [V] - [V]
r52952[0...3] CO: Armature current/field current scan values / Ia/If sc_values
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 6850, 6851,
6912
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: p2002 Expert list: 1
Min Max Factory setting
- [A] - [A] - [A]