2 Parameters
2.2 List of parameters
SINAMICS DCM
348 List Manual (LH8), 02/2015, 6RX1800-0ED76
The combination of device ID (r8909) and DAP ID (r8959) uniquely identifies a PROFINET access point.
Note: DAP ID: Device Access Point ID
DAP ID = 20007 hex: SINAMICS CBE20 V4.5
DAP ID = 20008 hex: SINAMICS CBE20 V4.6
DAP ID = 20009 hex: SINAMICS CBE20 V4.7
DAP ID = 20209 hex: SINAMICS CBE25 V4.7
Description: Displays the controller assignment of a PROFINET subslot on the actual drive object.
Index: [0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Note: Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
Description: Displays the controller assignment of a PROFINET subslot on the actual drive object.
Index: [0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Dependency: Refer to: r8971, r8972
Note: Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
Description: Displays the IP address of the first PROFINET controller connected with the device via CBE20/CBE25.
r8960[0...2] PN subslot controller assignment / PN subslot assign
All objects Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 8 -
r8970[0...2] CBE2x subslot controller assignment / CBE2x subslot
CU_DC (PROFINET
CBE20), CU_DC_R
(PROFINET CBE20),
CU_DC_R_S
(PROFINET CBE20),
CU_DC_S
(PROFINET CBE20),
DC_CTRL (PROFINET
CBE20), DC_CTRL_R
(PROFINET CBE20),
DC_CTRL_R_S
(PROFINET CBE20),
DC_CTRL_S
(PROFINET CBE20),
TM150 (PROFINET
CBE20), TM15DI_DO
(PROFINET CBE20),
TM31 (PROFINET
CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 8 -
r8971[0...3] CBE2x IP Address Remote Controller 1 / CBE2x IP Rem Ctrl1
CU_DC (PROFINET
CBE20), CU_DC_R
(PROFINET CBE20),
CU_DC_R_S
(PROFINET CBE20),
CU_DC_S
(PROFINET CBE20)
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 255 -