SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
507
2 Parameters
2.2 List of parameters
Description: Sets the offset for fast analog inputs "Select input 3 to 6".
Index: [0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Description: Sets the signal processing for fast analog inputs "Select input 3 to 6".
Value: 0: Signal not controlled
1: Signal absolute value generation
2: Signal inverted
3: Signal absolute value generation inverted
Index: [0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Description: Sets the signal source for inverting the signals for fast analog inputs "Select input 3 to 6".
1 signal: Inversion
0 signal: No inversion
Index: [0] = Select input 3 (X177.1/2)
[1] = Select input 4 (X177.3/4)
[2] = Select input 5 (X177.5/6)
[3] = Select input 6 (X177.7/8)
Description: Sets the time constant for smoothing the signals for fast analog inputs "Select input 3 to 6".
p50732[0...3] Fast analog inputs offset / Fast AI offs
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2085, 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 0.00 [%]
p50733[0...3] Fast analog inputs signal processing / Fast AI sig
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2085, 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 0
p50734[0...3] BI: Fast analog inputs inversion / Fast AI inv
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2085, 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50735[0...3] Fast analog inputs smoothing time constant / Fast AI T
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2085, 2090
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 10000 [ms] 0 [ms]