2 Parameters
2.2 List of parameters
SINAMICS DCM
504 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for enabling analog input 1 (X177.27/28) on the CUD.
Note: 1 signal:
Analog input is enabled
0 signal:
Analog input is disabled (value = 0%)
Description: Sets the setpoint for the simulation of analog input 1 (X177.27/28) on the CUD.
Dependency: Refer to: p50719
Note: Simulation is selected using p50719 = 1.
Description: Setting to select the simulation of analog input 1 (X177.27/28) on the CUD.
Value: 0: Simulation deactivated
1: Simulation activated
Dependency: Refer to: p50717
Note: The setpoint for the simulation is set in p50717.
Description: Sets the scaling for analog input 2 (X177.29/30) on the CUD.
The value indicates the percentage value for the mapping of an input voltage of 10 V at the analog input.
Example:
p50721 = 90%
--> 10 V is scaled to 90 %
--> 5 V corresponds to 45 %
Note: AI: Analog Input
p50716 BI: CUD analog input 1 signal source for enable / CUD AI 1 ena sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2080
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1
p50717 CUD analog input 1 simulation setpoint / CUD AI 1 sim setp
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2080
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-130.0 [%] 130.0 [%] 0.0 [%]
p50719 CUD analog input 1 simulation selection / CUD AI 1 sim sel
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2080
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50721[0...n] CUD analog input 2 scaling / CUD AI 2 scal
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 2080
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-1000.0 [%] 1000.0 [%] 100.0 [%]

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals