2 Parameters
2.2 List of parameters
SINAMICS DCM
634 List Manual (LH8), 02/2015, 6RX1800-0ED76
Note: Re bit 00:
1 signal: The relay output for the line contactor is activated via binector input p51619.
0 signal: The relay output for the line contactor is de-activated via binector input p51619.
Description: Display and connector output for the status in the event of an E stop (emergency stop).
Description: Displays the state of the motor interface.
Dependency: Refer to: p50486, p50487, p50488, p50489
Refer to: F60025, F60026, F60027, F60028
Description: Displays the state of temperature monitoring on the motor interface.
Dependency: Refer to: p50490, p50491, p50492
Refer to: F60029, A60032
r53100.0...1 CO/BO: E stop status / E stop stat
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 2070, 2580
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 No E stop Yes No 2070,
2580
01 E stop active Yes No 2070
r53120.0...3 CO/BO: Motor control checks / Mot mon state
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 8035
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Brush length too short Yes (fault) No -
01 Poor bearing condition Yes (fault) No -
02 Motor fan fault Yes (fault) No -
03 Motor temperature too high Yes (fault) No -
r53130.0...1 CO/BO: Motor interface temperature monitoring state / Mot temp_mon
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 8030
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Motor temperature alarm Yes No -
01 Motor temperature fault Yes No -