2 Parameters
2.2 List of parameters
SINAMICS DCM
442 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the fixed factor for the main setpoint.
Dependency: Refer to: p50322
Description: Sets the fixed factor for the additional setpoint.
Dependency: Refer to: p50323
Description: Sets the signal source for the variable factor for the main setpoint.
Dependency: Refer to: p50320
Description: Sets the signal source for the variable factor for the additional setpoint.
Dependency: Refer to: p50321
Description: Sets the unit for the ramp-function generator times.
Value: 0: Second
1: Minute
p50320[0...n] Setpoint processing main setpoint factor / m_set_factor
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-300.00 [%] 300.00 [%] 100.00 [%]
p50321[0...n] Setpoint processing additional setpoint factor / Add_set_factor
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-300.00 [%] 300.00 [%] 100.00 [%]
p50322[0...n] CI: Setpoint processing signal source for main setpoint factor / M set factor sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 1
p50323[0...n] CI: Setpoint processing signal source for additional setpoint factor / Add set fac sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 1
p50330[0...n] RFG time unit / RFG time unit
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 3150, 3152
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0