2 Parameters
2.2 List of parameters
Description: Sets the ramp-up time for ramp-function generator parameter set 2.
Description: Sets the ramp-down time for ramp-function generator parameter set 2.
Description: Sets the initial rounding for ramp-function generator parameter set 2.
Dependency: Refer to: p50295
Description: Sets the final rounding for ramp-function generator parameter set 2.
Dependency: Refer to: p50295
Description: Sets the ramp-up time for ramp-function generator parameter set 3.
p50307[0...n] RFG ramp-up time 2 / RFG t_ramp-up 2
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 650.00 [s] 10.00 [s]
p50308[0...n] RFG ramp-down time 2 / RFG ramp-dn time 2
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 650.00 [s] 10.00 [s]
p50309[0...n] RFG initial rounding 2 / RFG init rndg 2
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 100.00 [s] 0.00 [s]
p50310[0...n] RFG final rounding 2 / RFG fin rndg 2
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 100.00 [s] 0.00 [s]
p50311[0...n] RFG ramp-up time 3 / RFG t_ramp-up 3
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.00 [s] 650.00 [s] 10.00 [s]