EasyManua.ls Logo

Siemens SINAMICS DCM - Actual Topology Number of Indices; Act Topo Indices; BICO BI;CI Parameters to De-Activated Drive Objects; BICO BO;CO Parameters to De-Activated Drive Objects

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
358 List Manual (LH8), 02/2015, 6RX1800-0ED76
Dependency: Refer to: p9495, p9497, p9498, p9499
Note: The BI/CI parameters involved are listed in p9498[0...29] (signal sink).
The associated BO/CO parameters are listed in p9499[0...29] (signal source).
After p9496 = 1, 2 the following applies:
- p9497 = 0
- p9496 = 0
Description: Displays the number of saved BICO interconnections to drive objects that are either not capable of operation or have
been deactivated.
BO/CO parameters are on the drive object that is either not capable of operation or has been deactivated (signal
source).
Dependency: Refer to: p9495, p9496, p9498, p9499
Description: Displays the saved BI/CI parameters (signal sink), whose source is located on drive objects that are either not
capable of operation or have been deactivated.
Dependency: Refer to: p9495, p9496, p9497, p9499
Note: A BICO interconnection (signal sink, signal source) is displayed in the same index of p9498 and p9499.
Description: Displays the saved BO/CO parameters (signal source), which are located on drive objects that are either not capable
of operation or have been deactivated.
Dependency: Refer to: p9495, p9496, p9497, p9498
Note: A BICO interconnection (signal sink, signal source) is displayed in the same index of p9498 and p9499.
Description: Displays the number of indices of the actual topology.
Dependency: Refer to: r9901
p9497 BICO interconnections to de-activated drive objects number / Interconn obj qty
All objects Can be changed: T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 65535 0
p9498[0...29] BICO BI/CI parameters to de-activated drive objects / BI/CI to deact obj
All objects Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p9499[0...29] BICO BO/CO parameters to de-activated drive objects / BO/CO to deact obj
All objects Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Commands Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
r9900 Actual topology number of indices / Act topo indices
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Topology Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -