For devices with 575 V:
- 0 corresponds to -1036.2 V
- 32767 corresponds to 0 V
- 65535 corresponds to +1036.2 V
For devices with 1000 V:
- 0 corresponds to -1795.2 V
- 32767 corresponds to 0 V
- 65535 corresponds to +1795.2 V
Index: [0] = Phase VU
[1] = Phase VW
[2] = Voltage CV
[3] = Voltage CD
[4] = Voltage S13V
Dependency: Refer to: r52922, r52923
Note: This parameter is used solely for internal diagnostics.
Description: Display and connector output for the raw values from the measurements of Power Stack ASIC 2.
For voltage channels:
- 0 corresponds to -825.0 V
- 32767 corresponds to 0 V
- 65535 corresponds to +825.0 V
For the current channel:
- 49151 corresponds to 0 A
For devices with rated field current = 3A:
- 8218 corresponds to 3 A
For devices with rated field current = 5 A:
- 9065 corresponds to 5 A
For devices with rated field current = 10 A:
- 9065 corresponds to 10 A
For devices with rated field current = 15 A:
- 29108 corresponds to 15 A
For devices with rated field current = 25 A:
- 15746 corresponds to 25 A
For devices with rated field current = 30 A & A7115:
- 9065 corresponds to 30 A
For devices with rated field current = 30 A & A7116:
- 24608 corresponds to 30 A
For devices with rated field current = 40 A:
- 16427 corresponds to 40 A
For devices with rated field current = 85 A:
- 14382 corresponds to 85 A
Index: [0] = Raw value voltage 3U3W
[1] = Raw value voltage 3C3D
[2] = Raw value field current
Dependency: Refer to: r52921, r52923
Note: This parameter is used solely for internal diagnostics.
r52922[0...2] CO: Measurement results ASIC 2 raw values / Meas res ASIC2 raw
DC_CTRL Can be changed: - Calculated: - Access level: 4
Data type: Unsigned16 Dyn. index: - Func. diagram: 8054
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -