EasyManua.ls Logo

Siemens SINAMICS DCM - CI: Speed Limiting Controller Signal Source for Neg Torque Limit; CI: Speed Limiting Controller Signal Source for Pos Torque Limit; Speed Limiting Controller Max Speed Neg Direction of Rotation; Speed Limiting Controller Max Speed Pos Direction of Rotation

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
469
2 Parameters
2.2 List of parameters
Description: Sets the signal source for the positive torque limit on the speed limiting controller.
Dependency: Refer to: r52136
Note: This parameter specifies which parameter is to be injected as the limit value for torque limiting 1 (r52136).
Description: Sets the signal source for the negative torque limit on the speed limiting controller.
Dependency: Refer to: r52137
Note: This parameter specifies which parameter is to be injected as the limit value for torque limiting 2 (r52137).
Description: Sets the maximum speed for the positive direction of rotation on the speed limiting controller.
Description: Sets the maximum speed for the negative direction of rotation on the speed limiting controller.
Description: Sets the P gain on the speed limiting controller.
p50510 CI: Speed limiting controller signal source for pos torque limit / T lim pos sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52002[0]
p50511 CI: Speed limiting controller signal source for neg torque limit / T lim neg sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52004[0]
p50512[0...n] Speed limiting controller max speed pos direction of rotation / n_max pos dir rot
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 200.0 [%] 105.0 [%]
p50513[0...n] Speed limiting controller max speed neg direction of rotation / n_max neg dir
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.0 [%] 0.0 [%] -105.0 [%]
p50515[0...n] Speed limiting controller P gain / n_lim Kp
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6835
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.10 200.00 3.00