SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
565
2 Parameters
2.2 List of parameters
Description: Display and connector output for the braking distance required as increments of the pulse encoder defined in p0400.
The pulse encoder to be used must be selected using p50331.
The required braking distance is calculated assuming that the speed setpoint at the ramp-function generator input
has been set to 0 and the speed actual value is approaching 0, taking the set ramp-down time and roundings into
consideration.
Note: For p0400[p50331] = 0, a braking distance of 0 is displayed.
The braking distance calculation is only correct if the ramp-down time and the roundings do not change during
braking (p50302, r00899.5, p50637, p50638).
Description: Displays the integrated temperature sensors.
Note: The display is independent of the temperature sensor status and only indicates the desired state.
Description: Display and connector output for the device's temperature outputs.
Index: [0] = Temperature 1
[1] = Temperature 2
[2] = Temperature 3
[3] = Gating module temperature
[4] = CUD Control Unit temperature
Note: Temperature sensors which are not in use return a high negative value (approx. -200 °C).
Description: Display and connector output for the motor temperature.
r52048 CO: Ramp-function generator braking distance (FloatingPoint32) / RFG br dist float
DC_CTRL Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3152
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r52049 Temperature sensor available / Temp_sens avail
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: Unsigned16 Dyn. index: - Func. diagram: 6960
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Temperature sensor XT5 Available Not present 6960
01 Temperature sensor XT6 Available Not present 6960
02 Temperature sensor XT7 Available Not present 6960
03 Gating module temperature sensor Available Not present 6960
r52050[0...4] CO: Temperature sensor display / Temp sensor disp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8047, 8048
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52051 CO: Motor temperature output / Mot temp outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 8030
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals