2 Parameters
2.2 List of parameters
SINAMICS DCM
282 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the scaling of the output signals for the free measurement function.
Index: [0] = Signal 1
[1] = Signal 2
[2] = Signal 3
[3] = Signal 4
[4] = Signal 5
Note: The parameter cannot be changed when the measurement function has been started (r4706 = 2, 3).
Description: Sets the number of cycles of a multiple trace.
The multiple trace is de-activated with a value = 0.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Refer to: r4841, p4844
Notice: A multiple trace can have a negative impact on the total system performance.
From their inherent principle of operation, flash memory cards are subject to wear as a result of write operations. As
a consequence, the lifetime of flash memory cards is reduced when using the multiple trace functionality.
Description: Displays the currently running cycle (including deadtime) of the multiple trace.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Refer to: p4840, p4844
Description: Sets the number of ring buffer files for the measurement results of the multiple trace.
Index: [0] = Trace 0
[1] = Trace 1
p4835[0...4] Function generator free measurement function scaling / FG fr MeasFct scal
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
-200.00000 [%] 200.00000 [%] 100.00000 [%]
p4840[0...1] MTrace cycle number setting / Cycle number
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 4294967295 0
r4841[0...1] MTrace cycle actual display / Cycle act display
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - -
p4844[0...1] MTrace ring buffer files number / Ring buff file qty
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
5 5 5