2 Parameters
2.2 List of parameters
Description: Sets the signal sources for negative limiting after the ramp-function generator (setpoint limiting).
Note: The maximum of the signals is forwarded to the limiter via connector input p50633[0 to 3].
Description: Sets the signal sources for the input signals in the case of limiting after the ramp-function generator (setpoint
limiting).
Note: The signals via connector input p50634[0 to 1] are added to the input and forwarded to "Limiting after ramp-function
generator".
Description: Sets the signal source for the ramp-function generator's setpoint.
Description: Sets the signal sources for the valuation factors for ramp-function generator parameter set 1.
Index: [0] = Ramp-up time and ramp-down time
[1] = Initial rounding and final rounding
[2] = Ramp-up time
[3] = Ramp-down time
[4] = Initial rounding
[5] = Final rounding
Dependency: Refer to: p50303, p50304, p50305, p50306
p50633[0...3] CI: RFG signal source for negative limiting after RFG / RFG neg lim sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 3155
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - [0] 52210[0]
[1] 52210[1]
[2] 52210[2]
[3] 52210[3]
p50634[0...1] CI: RFG input signal for limiting after RFG / RFG lim inp sig
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 3155
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - [0] 52190[0]
[1] 0
p50635[0...n] CI: Setpoint processing signal source for RFG setpoint / RFG set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52194[0]
p50636[0...5] CI: RFG signal source for valuation factor 1 / RFG val_f 1 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 3150
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 1