2 Parameters
2.2 List of parameters
SINAMICS DCM
466 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for triggering fault F60026 "Bearing condition".
Dependency: Refer to: r53120
Refer to: F60026
Note: The fault is triggered with a delay.
The signal is available via binector output r53120.1 for further interconnection.
Description: Sets the signal source for triggering fault F60027 "Motor fan".
Dependency: Refer to: r53120
Refer to: F60027
Note: The fault is triggered with a delay.
The signal is available via binector output r53210.0 for further interconnection.
Description: Sets the signal source for triggering fault F60028 "Motor temperature".
Dependency: Refer to: r53120
Refer to: F60028
Note: The fault is triggered with a delay.
The signal is available via binector output r53210.3 for further interconnection.
Description: Sets the temperature sensor for monitoring the motor temperature.
Value: 0: No sensor
1: KTY84
2: PTC thermistor R_rated 600
3: PTC thermistor R_rated 1200
4: PTC thermistor R_rated 1330
5: PTC thermistor R_rated 2660
p50487 BI: Motor interface signal source for bearing condition / Mot brg cond sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 8035
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50488 BI: Motor interface signal source for motor fan / Mot mot fan sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 8035
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50489 BI: Motor interface signal source for motor temperature / Mot mot temp sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 8035
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50490 Motor interface temperature sensor / Mot temp sensor
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 8030
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 8 0