2 Parameters
2.2 List of parameters
SINAMICS DCM
426 List Manual (LH8), 02/2015, 6RX1800-0ED76
If p50230 = 0:
The integral component of the speed controller is set to the instantaneous value of the signal present at connector
input p50631.
If p50230 > 0:
The integral component of the speed controller is tracked continuously during the time set to the value of the signal
present at connector input p50631.
Description: Setting for enabling the proportional component for the speed controller.
Value: 0: Without proportional component
1: With proportional component
Description: Sets the dynamic response of the speed control circuit as the default for the speed controller optimization run.
Recommendation: On drives with gear backlash, for example, optimization should be started commencing with low dynamic response
values at and above 10%.
On drives with maximum requirements in terms of synchronous operation and dynamic response, values of up to 100
% can be selected.
Note: If this value is changed, the optimization run for the speed controller will have to be performed again before the new
value is applied.
Description: Sets the natural frequency of a PT2 element for the reference model of the speed controller.
Recommendation: The reference model is correctly set when the characteristics of r52154 (reference model output) and r52167 (actual
speed value) are virtually identical when the I component of the speed controller is disabled.
Dependency: In conjunction with p50238 and p50239, the characteristics (in time) of the P-controlled speed control loop can be
emulated.
Refer to: p50238, p50239
p50234[0...n] Speed controller proportional component enable / n_ctr P_comp ena
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 6815
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 1
p50236 Speed controller optimization speed controller dynamic response / n_ctr_opt dyn
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2660
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
10 [%] 100 [%] 75 [%]
p50237[0...n] Speed controller reference model natural frequency / n_ctrl ref_m fn
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6812
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0.0 [Hz] 150.0 [Hz] 0.0 [Hz]