EasyManua.ls Logo

Siemens SINAMICS DCM - Measuring Function Control; Meas Fct Ctrl; Trace Control; Trace Control; Trace Options; Trace Options; Trace Status; Trace Status

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
256 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Setting to control the trace function.
Value: 0: Stop trace
1: Start trace
2: Start trace and save values
Index: [0] = Trace 0
[1] = Trace 1
Description: Setting to control the measurement function.
Value: 0: Stop measuring function
1: Start measuring function
2: Measuring function check parameterization
3: Start measuring function without enable signals
Description: Sets the options for the trace.
Index: [0] = Trace 0
[1] = Trace 1
Dependency: Refer to: p4700
Note: Re bit 00:
0: The trace starts with p4700 as before.
1: When powering up, the trace starts immediately with the saved parameter settings with the start of the time slices.
Description: Displays the actual status of the trace.
p4700[0...1] Trace control / Trace control
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 2 0
p4701 Measuring function control / Meas fct ctrl
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: U, T Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 3 0
p4703[0...1] Trace options / Trace options
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: T Calculated: - Access level: 3
Data type: Unsigned16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Automatically start trace with time slices Yes No -
r4705[0...1] Trace status / Trace status
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 3
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Trace and function generator Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 0
Min Max Factory setting
0 4 -

Table of Contents

Other manuals for Siemens SINAMICS DCM