2 Parameters
2.2 List of parameters
SINAMICS DCM
28 List Manual (LH8), 02/2015, 6RX1800-0ED76
2.2 List of parameters
Product: SINAMICS DC MASTER, Version: 4702900, Language: eng
Objects: CU_DC, CU_DC_R, CU_DC_R_S, CU_DC_S, DC_CTRL, DC_CTRL_R, DC_CTRL_R_S, DC_CTRL_S, TM150, TM15DI_DO, TM31
Product: SINAMICS DC MASTER OA, Version: 1401800, Language: eng
Objects: DC_CTRL
Description: Operating display for the Control Unit (CU).
Value: 0: Operation
10: Ready
20: Wait for run-up
25: Wait for automatic FW update of DRIVE-CLiQ components
31: Commissioning software download active
33: Remove/acknowledge topology error
34: Exit commissioning mode
35: Carry out first commissioning
70: Initialization
80: Reset active
99: Internal software error
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
Description: Operating display for the drive.
Value: 0: o0.0 No torque direction switched on
1: o0.1 Torque direction I switched on
2: o0.2 Torque direction II switched on
9: o0.9 Wait for enable from master
10: o1.0 Wait time for brake opening time running
11: o1.1 Wait for operating enable at terminal 13
12: o1.2 Wait for operating enable (signal source acc. to p0852)
13: o1.3 Wait time after withdrawing a jog command running
14: o1.4 Wait until the field has been reversed
15: o1.5 Wait for operating enable from the optimization run
16: o1.6 Wait for withdrawal of the immediate pulse inhibit
17: o1.7 Wait for SINAMICS DCM connected in parallel in status o0.0
18: o1.8 Operating state o1.8
19: o1.9 Operating state o1.9
20: o2.0 Wait for setpoint
21: o2.1 Operating state o2.1
22: o2.2 Operating state o2.2
30: o3.0 Wait for the thyristor check to be completed
31: o3.1 Wait for line supply symmetry
32: o3.2 Wait for a DC contactor to pick up
33: o3.3 Wait for the feedback signal "main contactor"
34: o3.4 Operating state o3.4
35: o3.5 Operating state o3.5
40: o4.0 Wait for voltage at 1U1, 1V1, 1W1
41: o4.1 Wait until fuse monitoring signals OK
42: o4.2 Operating state o4.2
r0002 Control Unit operating display / CU op_display
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: 2651
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 99 -
r0002 Drive operating display / Drv op_display
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: 2651
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 129 -