SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
29
2 Parameters
2.2 List of parameters
43: o4.3 Operating state o4.3
44: o4.4 Operating state o4.4
45: o4.5 Wait until CCP pre-charged
50: o5.0 Wait for field current actual value
51: o5.1 Wait for voltage at 3U1, 3W1
52: o5.2 Operating state o5.2
53: o5.3 Operating state o5.3
60: o6.0 Wait until auxiliaries have been switched on
61: o6.1 Wait for small setpoint
62: o6.2 Operating state o6.2
63: o6.3 Operating state o6.3
70: o7.0 Wait for power-on via terminal 12
71: o7.1 Wait for power-on (signal source according to p0840)
72: o7.2 Stopping saved
73: o7.3 Wait for parallel master to power up
74: o7.4 Start of an optimization run
75: o7.5 Wait until SINAMICS DCM conn. in par. are rdy to switch on
76: o7.6 Operating state o7.6
77: o7.7 Operating state o7.7
78: o7.8 Operating state o7.8
79: o7.9 Operating state o7.9
80: o8.0 Switching on inhibited
81: o8.1 Simulation mode active
82: o8.2 Operating state o8.2
83: o8.3 Operating state o8.3
90: o9.0 Operating state o9.0
91: o9.1 Quick stop (OFF3) (signal source acc. to p0848) present
92: o9.2 Quick stop (OFF3) (signal source acc. to p0849) present
93: o9.3 Quick stop (OFF3) saved
94: o9.4 SS1 command (Safe Stop 1) present
95: o9.5 Operating state o9.5
96: o9.6 Operating state o9.6
97: o9.7 Operating state o9.7
98: o9.8 Operating state o9.8
99: o9.9 Operating state o9.9
100: o10.0 Operating state o10.0
101: o10.1 Voltage disconnect (OFF2) (signal source acc. to p0844)
102: o10.2 Voltage disconnect (OFF2) (signal source acc. to p0845)
103: o10.3 E stop (safety shutdown) (terminal 105/106)
104: o10.4 STO command (Safe Torque Off) present
105: o10.5 Operating state o10.5
106: o10.6 CUD right
107: o10.7 Operating state o10.7
108: o10.8 Operating state o10.8
109: o10.9 Operating state o10.9
110: o11.0 Fault present
120: o12.0 Initializ. of line voltage sensing for field in progress
121: o12.1 Initializ. of line voltage sensing for armature in progr.
122: o12.2 Operating state o12.2
123: o12.3 Reading out data of the gating modules
124: o12.4 Offset calibr. of curr. act. val. sensing being performed
125: o12.5 Read out data from the power unit
126: o12.6 Initializing the second processor (TMS320)
127: o12.7 Operating state o12.7
128: o12.8 Operating state o12.8
129: o12.9 Operating state o12.9
Dependency: Refer to: r0046
Notice: For several missing enable signals, the corresponding value with the highest number is displayed.
Note: OC: Operating condition
RFG: Ramp-function generator
COMM: Commissioning