SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
207
2 Parameters
2.2 List of parameters
Description: Sets the suppression of r2139.3 "Fault present" for certain fault responses.
Dependency: Refer to: p0491, r2139
Note: Depending on the suppression of a fault reaction in this parameter, r2139.1 "Acknowledgement required" is set when
at least one fault occurs.
Re bit 08:
The suppression is only effective if p0491 = 1.
Description: Display and connector output for the load speed for APC (Advanced Positioning Control).
Dependency: Refer to: r3771
Description: Display and connector output for the speed actual values for APC (Advanced Positioning Control).
Index 0:
Displays the smoothed load speed.
Index 1:
Displays the load/motor speed actual value weighted with p3702 for p3700.8=1.
Index: [0] = Load actual value speed smoothed
[1] = Load/motor actual speed weighted
Dependency: Refer to: p1441, r3770
Description: Exits quick commissioning (p0010 = 1) with automatic calculation of all parameters of all existing drive data sets that
depend on the entries made during quick commissioning.
p3135 Suppress active fault / Supp act flt
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: U, T Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: - Func. diagram: 8060
P-Group: Messages Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0000 0000 0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
08 Suppression of fault response ENCODER ON OFF -
10 Suppression of fault response NONE ON OFF -
r3770 CO: Load speed / n_load
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 1580, 4711
P-Group: Setpoints Unit group: 3_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
r3771[0...1] CO: Load speed smoothed / n_load smooth
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 1580, 4711
P-Group: Setpoints Unit group: 3_1 Unit selection: p0505
Not for motor type: - Scaling: p2000 Expert list: 1
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
p3900 Completion of quick commissioning / Compl quick_comm
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: C2(1) Calculated: - Access level: 1
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Displays, signals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 0