2 Parameters
2.2 List of parameters
SINAMICS DCM
488 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for the acceleration value for inertia compensation.
Description: Sets the signal source for the setpoint/actual value difference on the speed controller.
Dependency: Refer to: r52164
Note: The setpoint/actual value difference for the speed controller is available in r52164 for further interconnection.
Description: Sets the signal source for setpoint 1 on the speed controller.
Dependency: Refer to: p50622, p50623, p50624, r52165
Note: The setpoint/actual value difference (r52165) results from setpoint 1 and 2 (p50621, p50622) and actual value 1 and
2 (p50623, p50624).
Description: Sets the signal source for setpoint 2 on the speed controller.
Dependency: Refer to: p50621, p50623, p50624, r52165
Note: The setpoint/actual value difference (r52165) results from setpoint 1 and 2 (p50621, p50622) and actual value 1 and
2 (p50623, p50624).
Description: Sets the signal source for actual value 1 on the speed controller.
p50619 CI: Acceleration value for inertia compensation / Comp inert acc val
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6820
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52191[0]
p50620 CI: Speed controller setpoint/actual value difference signal source / n_ctr set/ac sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6815
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52165[0]
p50621 CI: Speed controller setpoint 1 signal source / n_ctr set 1 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52176[0]
p50622 CI: Speed controller setpoint 2 signal source / n_ctr set 2 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52174[0]
p50623 CI: Signal source for speed controller actual value 1 / n_ctr act 1 sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52179[0]