2 Parameters
2.2 List of parameters
SINAMICS DCM
550 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal sources for transmit data when operating the device as a master on the parallel interface.
Index: [0] = Word 1
[1] = Word 2
[2] = Word 3
[3] = Word 4
[4] = Word 5
[5] = Word 6
[6] = Word 7
[7] = Word 8
[8] = Word 9
[9] = Word 10
[10] = Word 11
[11] = Word 12
[12] = Word 13
[13] = Word 14
[14] = Word 15
[15] = Word 16
Note: This parameter is used to define the transmit data and its position in the transmit telegram.
[0]: Word 1 in the telegram
...
[4]: Word 5 in the telegram
[5]: Word 1 in the telegram
...
[9]: Word 5 in the telegram
...
Description: Sets the number of CUDs, which communicate with one another via the parallel switching interface.
This setting is intended so that every device connected to the parallel switching interface can monitor whether all
devices are active and/or available.
Each of the devices connected to the parallel switching interface continually monitors whether all of the devices
regularly send telegrams.
"Device connected to the parallel switching interface" is every CUD, at which p51800 > 0 .
"Regularly sending telegrams" means that the time between two send telegrams from the same device must be less
than 100 ms.
Note: - If the number set here is less than the actual number of devices connected to the parallel switching interface, then
failure of some of the devices is ignored.
- A setting of 1 means that the monitoring is inactive.
p51814[0...15] CI: Parallel interface master transmit data / PI master tr data
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Integer16 Dyn. index: - Func. diagram: 9355
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: 4000H Expert list: 1
Min Max Factory setting
- - 0
p51815 Parallel interface number of devices / Par_IF device qty
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned8 Dyn. index: - Func. diagram: 9350
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 16 1

Table of Contents

Other manuals for Siemens SINAMICS DCM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS DCM and is the answer not in the manual?

Siemens SINAMICS DCM Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS DCM
CategoryMedia Converter
LanguageEnglish

Related product manuals