SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
407
2 Parameters
2.2 List of parameters
Description: Setting of the field current for a motor flux of 60 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50131 and less than p50133 can be set.
Description: Setting of the field current for a motor flux of 65 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50132 and less than p50134 can be set.
Description: Setting of the field current for a motor flux of 70 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50133 and less than p50135 can be set.
Description: Setting of the field current for a motor flux of 75 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50134 and less than p50136 can be set.
p50132[0...n] Field current for motor flux 60 % / I_field flux 60%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 44.6 [%]
p50133[0...n] Field current for motor flux 65 % / I_field flux 65%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 48.9 [%]
p50134[0...n] Field current for motor flux 70 % / I_field flux 70%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 53.6 [%]
p50135[0...n] Field current for motor flux 75 % / I_field flux 75%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 58.9 [%]