EasyManua.ls Logo

Siemens SINAMICS DCM - Field Current for Motor Flux 0 %; I_Field Flux 0%; Field Current for Motor Flux 10 %; I_Field Flux 10%; Field Current for Motor Flux 15 %; I_Field Flux 15%; Field Current for Motor Flux 5 %; I_Field Flux 5%

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
404 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Setting of the field current for a motor flux of 0 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values less than p50121 can be set.
Description: Setting of the field current for a motor flux of 5 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50120 and less than p50122 can be set.
Description: Setting of the field current for a motor flux of 10 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50121 and less than p50123 can be set.
Description: Setting of the field current for a motor flux of 15 %.
Note: This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50122 and less than p50124 can be set.
p50120[0...n] Field current for motor flux 0 % / I_field flux 0%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 0.0 [%]
p50121[0...n] Field current for motor flux 5 % / I_field flux 5%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 3.7 [%]
p50122[0...n] Field current for motor flux 10 % / I_field flux 10%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 7.3 [%]
p50123[0...n] Field current for motor flux 15 % / I_field flux 15%
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6900, 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
0.0 [%] 100.0 [%] 11.0 [%]

Table of Contents

Other manuals for Siemens SINAMICS DCM

Related product manuals