SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
459
2 Parameters
2.2 List of parameters
Description: Sets the signal source for the selection of the connectors (p50436[0 to 7]).
Description: Sets the signal sources for generating the jog setpoint (CO: r52202).
Description: Setting to enable or disable the impact of the individual jog setpoints when generating signal r53170.11, "Bypass
ramp-function generator".
Value: 0: Do not bypass
1: Bypass
Note: [0] = Enable bypassing of ramp-function generator at jog setpoint 0
...
[7] = Enable bypassing of ramp-function generator at jog setpoint 7
Description: Sets the signal source for the default setpoint when jog is not selected.
Description: Sets the signal source for the selection of the connectors (p50441[0 to 7]) for the creep setpoint.
Dependency: Refer to: p50441
p50435[0...7] BI: Jog setpoint signal source for connector selection / Jog set conn sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 3125
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p50436[0...7] CI: Signal source for jog setpoint / Jog set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 3125
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50437[0...7] Jog setpoint bypass ramp-function generator / Jog set bypass RFG
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 3125
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
p50438[0...n] CI: Jog signal source for default setpoint / Jog def set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 3125
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52208[0]
p50440[0...7] BI: Creep setpoint signal source for connector selection / Cr set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 3130
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0