SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
633
2 Parameters
2.2 List of parameters
Description: Control word for field current thresholds.
Description: Display and connector output for the "Wire break" message in the case of the CUD analog inputs.
Dependency: Refer to: F60046, F60047
Description: Display and connector output for the line contactor control.
Description: Displays the status of the line contactor control.
Dependency: Refer to: p51619
r53026.0...1 CO/BO: Field current messages / If messages
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 8025
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Field current less than minimum field
current threshold
Yes No -
01 Field current actual value less than field
current setpoint x
Yes No -
r53030.0...1 CO/BO: CUD analog inputs wire break message / CUD AI wire brk
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 2075, 2080
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 AI "Main setpoint" wire-break monitoring
responded
Yes No 2075
01 AI 1 (X177.27/28) Wire-break monitoring
responded
Yes No 2080
r53081.0...1 CO/BO: Sequence control line contactor control / Ctrl line cont
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 2651
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Line contactor ON OFF 2651
01 Line contactor inverted ON OFF 2651
r53082.0 CO/BO: Line contactor state / Line cont state
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: Unsigned16 Dyn. index: - Func. diagram: 2070
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Line contactor ON Yes No 2070