2 Parameters
2.2 List of parameters
SINAMICS DCM
486 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for the actual value on the speed controller.
Dependency: Refer to: p50083
Description: Sets the signal source for the input value on the field gating unit.
Description: Sets the signal sources for generating the field current setpoint (CO: r52275).
Dependency: Refer to: r52275
Description: Sets the signal source for the field current actual value for closed-loop field current control.
Description: Sets the signal sources for generating the upper limit of the field current setpoint (CO: r52273).
Dependency: Refer to: r50073, p50102, r52273
p50609[0...n] CI: Signal source for speed controller actual value / n_ctr act sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: CDS, p0170 Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p50610 CI: Signal source for field gating unit input value / Field g unit sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6915
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52252[0]
p50611[0...3] CI: Field curr setp limiting setpoint sig source / If_lim set sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6905
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - [0] 52277[0]
[1] 0
[2] 0
[3] 0
p50612[0...1] CI: Cl-loop field current ctrl sig source for field current act val / If_ctr If_ac sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6910
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - [0] 52266[0]
[1] 0
p50613[0...4] CI: Field current setpoint limiting sig source for var upper limit / If_li up li sig s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6905
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 1