2 Parameters
2.2 List of parameters
SINAMICS DCM
540 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for the connectors to be recorded by the recorder function.
Dependency: Refer to: p51701, p51702, p51703, p51704, p51705, p51706
Note: [0] = Signal source for the first connector to be recorded
[1] = Signal source for the second connector to be recorded
Description: Sets the signal source for the binectors to be recorded by the recorder function.
Dependency: Refer to: p51700, p51702, p51703, p51704, p51705, p51706
Note: [0] = Signal source for the first binector to be recorded
[1] = Signal source for the second binector to be recorded
Description: Setting to select the channels to be recorded.
Dependency: Refer to: p51700, p51701, p51703, p51704, p51705, p51706
Description: Sets the recording interval,
during which the signals selected with the channel selection parameters (p51702.0 to 3) are scanned and saved
internally.
Dependency: Refer to: p51700, p51701, p51702, p51704, p51705, p51706
p51700[0...1] CI: Signal source for connector recorder function / Rec fct con sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8050
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p51701[0...1] BI: Signal source for binector recorder function / Rec fct bin sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 8050
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p51702 Recorder function channel selection / Rec fct sel
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dyn. index: - Func. diagram: 8050
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1111 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Channel 0 Active Not active -
01 Channel 1 Active Not active -
02 Channel 2 Active Not active -
03 Channel 3 Active Not active -
p51703 Recorder function recording interval / Rec fct t_rec
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dyn. index: - Func. diagram: 8050
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 [s] 1000 [s] 1 [s]