EasyManua.ls Logo

Siemens SINAMICS DCM - BI: Signal Source for Binector Recorder Function; CI: Signal Source for Connector Recorder Function; Recorder Function Channel Selection; Rec Fct Sel; Recorder Function Recording Interval; Rec Fct T_Rec

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2 Parameters
2.2 List of parameters
SINAMICS DCM
540 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Sets the signal source for the connectors to be recorded by the recorder function.
Dependency: Refer to: p51701, p51702, p51703, p51704, p51705, p51706
Note: [0] = Signal source for the first connector to be recorded
[1] = Signal source for the second connector to be recorded
Description: Sets the signal source for the binectors to be recorded by the recorder function.
Dependency: Refer to: p51700, p51702, p51703, p51704, p51705, p51706
Note: [0] = Signal source for the first binector to be recorded
[1] = Signal source for the second binector to be recorded
Description: Setting to select the channels to be recorded.
Dependency: Refer to: p51700, p51701, p51703, p51704, p51705, p51706
Description: Sets the recording interval,
during which the signals selected with the channel selection parameters (p51702.0 to 3) are scanned and saved
internally.
Dependency: Refer to: p51700, p51701, p51702, p51704, p51705, p51706
p51700[0...1] CI: Signal source for connector recorder function / Rec fct con sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 8050
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 0
p51701[0...1] BI: Signal source for binector recorder function / Rec fct bin sig s
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 8050
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0
p51702 Recorder function channel selection / Rec fct sel
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dyn. index: - Func. diagram: 8050
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 1111 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Channel 0 Active Not active -
01 Channel 1 Active Not active -
02 Channel 2 Active Not active -
03 Channel 3 Active Not active -
p51703 Recorder function recording interval / Rec fct t_rec
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned32 Dyn. index: - Func. diagram: 8050
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
1 [s] 1000 [s] 1 [s]

Table of Contents

Other manuals for Siemens SINAMICS DCM

Related product manuals