2 Parameters
2.2 List of parameters
SINAMICS DCM
58 List Manual (LH8), 02/2015, 6RX1800-0ED76
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Displays the firmware version of the Sensor Module.
Dependency: Refer to: r0018, r0158, r0197, r0198
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
Description: Sets the component number for the Terminal Module.
This unique component number is assigned when parameterizing the topology.
Only component numbers can be entered into this parameter that correspond to a Terminal Module.
Description: Detects the Terminal Module assigned to this drive and data set.
Note: While p0154 = 1, the READY LED flashes green/orange or red/orange with 2 Hz at the appropriate Terminal Module.
Description: Displays the version of the EEPROM data of the Terminal Module.
Dependency: Refer to: r0147
Note: Example:
The value 1010100 should be interpreted as V01.01.01.00.
r0148[0...n] Sensor Module firmware version / SM FW version
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: EDS, p0140 Func. diagram: -
P-Group: Encoder Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
p0151 Terminal Module component number / TM comp_no
TM150, TM15DI_DO,
TM31
Can be changed: C1(4) Calculated: - Access level: 3
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: Data sets Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 199 0
p0154 Terminal Module detection via LED / TM detection LED
TM150, TM15DI_DO,
TM31
Can be changed: U, T Calculated: - Access level: 2
Data type: Unsigned8 Dyn. index: - Func. diagram: -
P-Group: Terminals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 0
r0157 Terminal Module EEPROM data version / TM EEPROM version
TM150, TM15DI_DO,
TM31
Can be changed: - Calculated: - Access level: 3
Data type: Unsigned32 Dyn. index: - Func. diagram: -
P-Group: Terminals Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -