EasyManua.ls Logo

Siemens SINAMICS DCM - Analog Input Main Actual Value Offset; AI M Act Offs; Analog Input Main Actual Value Scaling; AI M Act Scal; Analog Input Main Actual Value Signal Processing; AI M Act Sig; BI: Analog Input Main Actual Value Inversion; AI M Act Inv

Siemens SINAMICS DCM
1204 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
509
2 Parameters
2.2 List of parameters
Description: Sets the input voltage (8 - 270 V) for scaling to 100%.
Rated value of the input voltage at n_max (= tachometer voltage at maximum speed).
This parameter specifies the maximum speed at p50083 = 1.
Note: AI: Analog Input
Example:
p50741 = 60
--> 30 V is scaled to 50 % for analog input main actual value scaled
--> 60 V is scaled to 100% for analog input main actual value scaled
Description: Sets the offset for the "main actual value" (XT1.103/104).
Description: Sets the mode for signal processing for the "main actual value" analog input (XT1.103/104).
Value: 0: Signal not controlled
1: Signal absolute value generation
2: Signal inverted
3: Signal absolute value generation inverted
Description: Sets the signal source for inverting the signal from the "main actual value" analog input (XT1.103/104).
0 signal: No inversion
1 signal: Inversion
p50741[0...n] Analog input main actual value scaling / AI m act scal
DC_CTRL Can be changed: C2(1), U, T Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 2075
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
-270.00 [V] 270.00 [V] 60.00 [V]
p50742 Analog input main actual value offset / AI m act offs
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 2075
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
-200.00 [%] 200.00 [%] 0.00 [%]
p50743 Analog input main actual value signal processing / AI m act sig
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: 2075
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 0
p50744 BI: Analog input main actual value inversion / AI m act inv
DC_CTRL Can be changed: T Calculated: - Access level: 2
Data type: Unsigned32 / Binary Dyn. index: - Func. diagram: 2075
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - 0

Table of Contents