2 Parameters
2.2 List of parameters
Description: Displays the GUID of all the OA applications installed on the memory card/device memory.
r4992[0...15]: GUID of OA application 1
r4992[16]: Major information of OA application 1
r4992[17]: Minor information of OA application 1
r4992[18...33]: GUID of OA application 2
r4992[34]: Major information of OA application 2
r4992[35]: Minor information of OA application 2, ...
Dependency: Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4993, r4994
Notice: If there is no OA application, then it is not possible to access an index.
Description: Displays the activation status of the OA applications installed on the memory card/device memory.
r4993[0]: Activates OA application 1
r4993[1]: Activates OA application 2, ...
Value: 0: OA application inactive
1: OA application active
Dependency: Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4994
Notice: If there is no OA application, then it is not possible to access an index.
Description: Displays the properties of all the OA applications installed on the memory card/device memory.
r4994[0]: Version of OA application 1
r4994[1]: Version of OA application 2, ...
Dependency: Refer to: r4985, r4986, r4987, r4988, r4989, r4990, r4991, r4992, r4993
Notice: If there is no OA application, then it is not possible to access an index.
Note: The parameter is only for internal Siemens diagnostics.
r4992[0...n] OA GUID ES / OA GUID ES
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned8 Dyn. index: r4987 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
r4993[0...n] OA activation status / OA act stat
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 4
Data type: Integer16 Dyn. index: r4985 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 -
r4994[0...n] OA properties / OA property
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: - Calculated: - Access level: 4
Data type: Unsigned32 Dyn. index: r4985 Func. diagram: -
P-Group: OEM range Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Properties diagnostics bit 0 Yes No -
01 Properties diagnostics bit 1 Yes No -
02 Properties diagnostics bit 2 Yes No -
03 OEM No Yes -
04 Properties diagnostics bit 4 Yes No -
05 Properties diagnostics bit 5 Yes No -