2 Parameters
2.2 List of parameters
SINAMICS DCM
582 List Manual (LH8), 02/2015, 6RX1800-0ED76
Description: Display and connector output for the speed setpoint calculated by the ramp-function generator.
Description: Display and connector output for the rise of the ramp-function generator output in relation to the time set in p50542.
Dependency: Refer to: p50542
Description: Display and connector output for the setpoint before the ramp-function generator.
Description: Display and connector output for the setpoint to the ramp-function generator.
Dependency: Refer to: p50648
Description: Display and connector output for the sum "main setpoint (limited) + additional setpoint" after setpoint reduction.
Dependency: Refer to: p51607, p51608, r52195
Note: Setpoint reduction is set via p51608 and activated/de-activated via binector input p51607.
r52190 CO: RFG speed setpoint output / RFG n_set outp
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3150, 3151,
3152, 3155
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52191 CO: RFG dy/dt rise in relation to p50542 / RFG dy/dt p50542
DC_CTRL Can be changed: - Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3152
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52192 CO: RFG setpoint before ramp-function generator / RFG set bef RFG
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3151, 3152
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52193 CO: Setpoint processing output to ramp-function generator / Outp to RFG
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]
r52194 CO: Setpoint processing setpoint after reduction / Set after reduc
DC_CTRL Can be changed: - Calculated: - Access level: 1
Data type: FloatingPoint32 Dyn. index: - Func. diagram: 3135
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- [%] - [%] - [%]