SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
49
2 Parameters
2.2 List of parameters
Description: Displays the "active/inactive" state of a drive object.
Value: 0: Drive object inactive
1: Drive object active
Dependency: Refer to: p0105
Description: The type of an existing drive object is entered into each index.
Value: 0: -
1: SINAMICS S
2: SINAMICS G
3: SINAMICS I
4: SINAMICS NX/CX32
6: SINAMICS DC
9: SINAMICS S110
10: ACTIVE INFEED CONTROL
11: SERVO
12: VECTOR
13: VECTORMV
14: VECTORGL
15: VECTOR3P
16: VECTORSL
17: DC_CTRL
18: VECTORM2C
19: VECTORDM
20: SMART INFEED CONTROL
21: RENEWABLE INFEED CONTROL
30: BASIC INFEED CONTROL
35: BRAKE MODULE M2C
40: ACTIVE INFEED CONTROLMV
41: BASIC INFEED CONTROLMV
42: ACTIVE INFEED CONTROLM2C
51: SINAMICS G120 230 (SingleDO-Drive which combines Device+Vector)
52: SINAMICSG120 240_2 (SingleDO-Drive which combines Device+Vector)
53: SINAMICS_G120_CU250S_V (SingleDO Drive combines Device+Vector)
54: SINAMICSG120 G120D(SingleDO-Drive which combines Device+Vector)
55: SINAMICS_G120_CU250S_S (SingleDO Drive combines Device+Servo)
56: SINAMICSG110M (SingleDO-Drive which combines Device+Vector)
57: SINAMICS ET200
58: Link variant for Sinamics Microbasissystem
70: HLA
100: TB30 (Terminal Board)
102: SINAMICS MV
150: DRIVE-CLiQ Hub Module
200: TM31 (Terminal Module)
201: TM41 (Terminal Module)
202: TM17 High Feature (Terminal Module)
203: TM15 (Terminal Module)
r0106 Drive object active/inactive / DO act/inact
All objects Can be changed: - Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: Closed-loop control Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 1 -
p0107[0...n] Drive object type / DO type
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed: C1(2) Calculated: - Access level: 2
Data type: Integer16 Dyn. index: - Func. diagram: -
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 600 0