SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
421
2 Parameters
2.2 List of parameters
Dependency: Refer to: p50204, p50629, r52178
Description: Sets the quality for band-stop 2.
Value: 0: Quality = 0.5
1: Quality = 1
2: Quality = 2
3: Quality = 3
Dependency: Refer to: p50203, p50629, r52178
Description: Sets the derivative-action time for the derivative-action element.
Dependency: Refer to: p50206, p50627, r52168, r52169
Description: Sets the smoothing time for the derivative-action element.
Dependency: Refer to: p50205, p50627, r52168, r52169
Description: Sets the signal source for the lead/lag element.
Dependency: Refer to: p50208, p50209, r52156
p50204[0...n] Band-stop 2 quality / Band-st 2 quality
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: Integer16 Dyn. index: DDS, p0180 Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 3 0
p50205[0...n] Derivative-action element derivative-action time / D-act el t_d-act
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 1000 [ms] 0 [ms]
p50206[0...n] Derivative-action element smoothing time / Der-act el t_DAE
DC_CTRL Can be changed: U, T Calculated: - Access level: 2
Data type: FloatingPoint32 Dyn. index: DDS, p0180 Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: - Expert list: 1
Min Max Factory setting
0 [ms] 100 [ms] 0 [ms]
p50207 CI: Lead/lag element signal source / Lead/lag elem S_s
DC_CTRL Can be changed: T Calculated: - Access level: 3
Data type: Unsigned32 / FloatingPoint32 Dyn. index: - Func. diagram: 6810
P-Group: - Unit group: - Unit selection: -
Not for motor type: - Scaling: PERCENT Expert list: 1
Min Max Factory setting
- - 52179[0]